Skip to content

Units, signs and filters

Most wrong crash results come from units, signs or filtering, not from the formulas. This page lists what crashmetrics expects.

Units

crashmetrics uses SI units, with a few exceptions that follow the protocols:

Quantity Unit Notes
Time s Always seconds. HIC windows and exceedance durations are given in ms (window_ms, duration_ms).
Acceleration (head, chest, headform) g Convert with to_g.
Vehicle acceleration (OLC, pulse) m/s² Negative while decelerating.
Force N Protocol limits in kN are stored in N (e.g. 3300 N).
Moment N m
Deflection, displacement, elongation mm Chest, ribs, knee slider, ligaments, intrusions.
Angular velocity rad/s DAMAGE and BrIC.
Viscous criterion m/s
Energy J or your solver's unit Energy checks are ratios, so any consistent unit works.

Converting LS-DYNA output:

from crashmetrics.signals import to_g, to_seconds

t = to_seconds(time_ms, "ms")          # "s", "ms", "us"
a = to_g(acc, "mm/ms^2")               # "m/s^2", "mm/s^2", "mm/ms^2", "g", ...
force_N = force_kN * 1000.0            # mm-ms-kg gives kN
moment_Nm = moment_kNmm                # kN mm equals N m

Sign conventions

crashmetrics follows SAE J211, as Euro NCAP and Bharat NCAP do. Where a protocol does not state the sign, the default is documented and can be switched:

Channel Default Switch
Femur and tibia axial force compression negative compression_negative=False
Neck Fz tension positive
Neck My / occipital condyle moment flexion positive, extension negative
Hybrid III chest deflection compression positive compression_negative=True
THOR abdomen IR-TRACC length shortens in compression value vs max_dx, see Protocol notes
Acetabulum Fx compression negative compression_negative=False
Iliac force negative under belt load loaded_negative=False
Knee slider displacement negative in compression (abs(min(D)))
Vehicle acceleration (pulse) negative while decelerating

Tip

If a peak comes out as 0 or tiny, the sign is usually the cause: check the channel's polarity against the table above.

Filter classes (CFC)

Filter every channel with the CFC its protocol gives, using cfc_filter(t, signal, cfc=...). The values used in the Euro NCAP and Bharat NCAP protocols:

Channel CFC
Head linear acceleration (dummy, headform) 1000
Head angular velocity for DAMAGE 60
Upper neck forces 1000 (600 for Nij)
Upper neck moments 600
Chest and rib deflections, IR-TRACC length and angles 180
Spine and chest accelerations 180
Pelvis, acetabulum, iliac, femur and tibia loads 600
Knee slider displacement 180
ES-2 rib deflections / abdominal and pubic forces 180 / 600
Flex-PLI moments and elongations 180
Vehicle acceleration for OLC 180

Check the CFC table of the protocol version you assess to.

The filter is the SAE J211-1 Appendix C digital filter: a 2-pole Butterworth run forward and backward (phaseless, 4-pole). It needs uniform sampling and pads each end by odd reflection (pad_ms, 10 ms by default) to limit start-up transients.

Time zero and windows

  • Time zero should be first contact (T0). Many criteria accept t_start / t_end to limit the evaluation window, for example the loading phase for neck loads (loading_phase_end).
  • Head impacts after rebound are not assessed in the protocols; cut the record or pass t_end when needed.

Numbers and rounding

Scores are rounded the way each protocol does it (for example 3 decimals for Euro NCAP legform points and Bharat NCAP region scores). Intermediate values are not rounded. Pass round_to=None where offered to keep exact values.