crashmetrics.pelvis¶
pelvis
¶
Pelvis criteria for frontal impact dummies.
Functions:
acetabulum_force: THOR resultant acetabulum force while Fx is compressive (Euro NCAP CP 005, Section 3.6.2).iliac_force_drop: Iliac force drop, a submarining indicator (CP 005, Section 3.6.1; Hybrid III 5th female and THOR).
Units: time in s, force in N. Filter with CFC 600.
acetabulum_force
¶
acetabulum_force(
time: ArrayLike,
fx: ArrayLike,
fy: ArrayLike,
fz: ArrayLike,
compression_negative: bool = True,
t_start: float | None = None,
t_end: float | None = None,
) -> PeakResult
THOR acetabulum force (Euro NCAP CP 005, Section 3.6.2).
F = max(sqrt(Fx^2 + Fy^2 + Fz^2)) over the time intervals where
the acetabulum Fx is compressive. Returns 0 (at the first sample) if
Fx is never compressive.
Parameters:
| Name | Type | Description | Default |
|---|---|---|---|
time
|
ArrayLike
|
1D time array in s. |
required |
fx
|
ArrayLike
|
Acetabulum forces, N. |
required |
fy
|
ArrayLike
|
Acetabulum forces, N. |
required |
fz
|
ArrayLike
|
Acetabulum forces, N. |
required |
compression_negative
|
bool
|
True if compressive Fx is negative (as for the Euro NCAP femur, whose compression is negative). CP 005 does not state the sign; check it against your channel polarity. |
True
|
t_start
|
float | None
|
Optional evaluation window, s. |
None
|
t_end
|
float | None
|
Optional evaluation window, s. |
None
|
iliac_force_drop
¶
iliac_force_drop(
time: ArrayLike,
force: ArrayLike,
interval: float = 0.001,
loaded_negative: bool = True,
t_start: float | None = None,
t_end: float | None = None,
) -> PeakResult
Iliac force drop (Euro NCAP CP 005, Section 3.6.1).
IFD = max(IFD(t)) with IFD(t) = F(t + 1 ms) - F(t), the
iliac force F at t + interval taken by linear interpolation.
Parameters:
| Name | Type | Description | Default |
|---|---|---|---|
time
|
ArrayLike
|
1D time array in s. |
required |
force
|
ArrayLike
|
Iliac force Fx, N. |
required |
interval
|
float
|
Look-ahead interval, s (1 ms in CP 005). |
0.001
|
loaded_negative
|
bool
|
True if the iliac force is negative under belt load, so that a sudden unloading (the belt sliding off the iliac crest) gives a positive IFD, as the CP 005 formula implies. If your channel is positive under load, pass False and the force is reversed. |
True
|
t_start
|
float | None
|
Optional window for t, s. |
None
|
t_end
|
float | None
|
Optional window for t, s. |
None
|
Returns:
| Type | Description |
|---|---|
PeakResult
|
Largest drop in N and the time t at which it starts. |